EMC Directive 2014/30/EU

The Finlab laboratory is able to perform measurements for the following environments and products: measures for industrial environments, residential / civil, electrical, medical, machine tools, welding equipment, UPS, electric drive systems for the photovoltaic industry, tools and laboratory lighting.

This Directive regulates the electromagnetic compatibility of equipment. It aims to ensure the functioning of the internal market by requiring equipment to comply with an adequate level of electromagnetic compatibility.  Member states are responsible for ensuring the safety on their territory and people's health, in particular of workers and consumers and, where appropriate, domestic animals and property, particularly in relation to the risks arising from the use of machines.

Reference Standards:

Generic standard for industrial environments EN 61000-6-4 (Part emission)

Generic standard for industrial environments EN 61000-6-2 (Part immunity)

Generic standard for residential EN 61000-6-3 (Part emission )

Generic standard for residential EN 61000-6-1 (Part immunity)

Product standard for household appliances and similar apparatus EN 55014-1 (emission side)

Product standard for household appliances and similar apparatus EN 55014-2 (Part immunity)

Product standard EN 60601-1-2 for electro-medical sector

Product standard EN 50370-1 for machine tools (Part emissions)

Product standard EN 50370-2 for machine tools (Part immunity)

Product standard for lifts EN 12015 (Part emissions)

Product standard for lifts EN 12016 (Part immunity)

Product standard for uninterruptable power supply (UPS ) EN 62040-2

Product standard for welders EN 60974-10

Product standard EN 61800-3 for electrical drives

Product standard EN 50130-4 for alarm systems

Product standard for lighting EN 55015 ( emission side )

Product standard for lighting EN 61547 (Part immunity)

Testing Standards: 

Radiated emissions CISPR 02/03/16

Conducted emissions CISPR 16-2-1 and CISPR 16-1-2

Harmonic current emissions EN 61000-3-2

Harmonic current emissions EN 61000-3-12

Emissions EN 61000-3-3 Flicker

Emissions of flicker EN 61000-3-11

Immunity to electrostatic discharge EN 61000-4-2

Immunity to radiated electromagnetic fields EN 61000-4-3

EN 61000-4-4 Immunity to fast transients

Immunity surge EN 61000-4-5

Immunity to conducted radio frequency EN 61000-4-6

Immunity to power frequency magnetic fields EN 61000-4-8

Immunity to magnetic fields at network frequency impulse EN 61000-4-9

Immunity to holes and to changes in network EN 61000-4-11

Fin SRL - Via Edison, 217 - 20019 Settimo Milanese (Milan) - Italy
Phone: +39 02 48904 62,  FAX +39 02 48903 38,  info@finlab.it,  P.IVA 11871420151